    Thin oil lubrication
    WGXYZA High Low Oil Station
     WGXYZA High low oil station is a oil lubrication deice combined of two parts ; high pressure part is 31.5MPa ,oil output 25L/min; and low pressure part is 0.4MPa ,oil output 16~125 L/min .This station holds units of filter, heater ,cooler etc. and function of safety , auto controller ,alarm etc .It is suitable for oil lubrication system of large scale equipment to lubricate hybrid bearing installed on the miller, rolling machine or electric the machine .Its working medium is industrial oil of N22~N320.According to the principle of dynamic and static pressure ,it uses the high system when the machine in starting , stopping or slow running ; uses the low system when running ordinary , to ensure the lubrication reliable on various speedy of large main machine ,and to prolong its life
    Example of order:
    A high-low oil station its high pressure is 31.5MPa, output 2.5L/min ,and low pressure is 0.4MPa, output 25L/min
    WGXYZ-25A high low oil station 
    Structure & Principle
    This station is consisted mainly of oil tanker (magnetic core mesh filter inner),low pressure pump device ,high pressure pump device ,twin barrel magnetic core mesh filter , heater ,cooler ,manual high pump , pipeline ,valve ,instrument panel ,electric controller etc . 
    Before starting main machine ,starts the low pump ,when its low filling pressure reached normal ,stars the high pump which suction port is connected to the pipeline of low pump. The high oil through high check valve flows to the static pressure bearing .When the high pressure reached a curtain value ,starts the main machine ,slow runs or stops. After main machine running normally then stops the high pump (exception the low running ),but the low pump must operate ordinary . The low pump suction oil from tanker ,then sends it pass check valve ,twin barrel mesh filter , cooler to the static pressure bearing too ,to maintain the main machine running ordinary .After stopped main machine ,if want filling oil by high or low pump timely ,can control by time relay to lubricate the point interrupt.
    The specific value of high or low pressure is controlled by high-low safety valve in the system.
    In the ordinary running of main machine , one low pump is working ,and another one is standing by . As the system pressure down at a value wanted , starts the ready pump , and then stops it while normal . If the pressure downing on still ,must sent an alarm ,and consider stopping the main machine.
    When the high plunger pump at fault , can fills oil by manual pump.
    Set the filter before the cooler , make the low viscidity oil passes the filter earlier , one filter at working , and another one at standing by , controlled by handle switch valve.
    Oil level higher or lower than a limit , are sent alarm by level signal , manual oil filling or stopping .
    Back oil passes the magnet mesh filter prepared in the tanker ,and can absorb the iron particulate at same time.
    Whole set of oil station is matched an instrument panel and an electric controller , to display operating data and to carry out at automatic , manual or alarm.
    A bimetallic electric contact thermometer installed on the tanker , when oil temp is too low sends a signal ,to open the heater by handle ,and stops automatically when reached an appointed temperature.

    A electric contact pressure type thermometer installed in the filling port , setting two limits of maximum and minimum temp needed ,to determine the cooler working or not.


    Appearance and dimensions:



    parameter/type
    WGXYZ WGXYZ WGXYZ WGXYZ WGXYZ WGXYZ
    16A 25A 40A 63A 100A 125A
    low system 
    pump type    LBZ-16 LBZ-25 LBZ-40 LBZ-63 LBZ-100 LBZ-125
     output L/min 16 25 40 63 100 125
    filling pressure MPa 0.4
     filling ℃ 40±3
    motor  type Y90S-4,V1 Y100L1-4,V1 Y112M-4,V1
     power 1.1 2.2 4
     velocity 1400 1400 1440
     tank m3 0.8 1.2 1.6
    high system 
     pump type     2.5MCY14-1B    
     output L/min     2.5    
    filling pressure MPa 31.5
    motor
     type Y112M-6 B35
     power 2.2
     velocity 940
     filter precision mm 0.08
     filter area m2 0.13 0.19 0.40
     cooling area m2 3 5 7
     consume of cooling water m3/h 1 1.5 3.6 5.7 9 11.25
     power of heater kW 3*4 3*4 6*4
     demission mm 1820*1130*1320 1880*1220*1650 /
    note the switch differential pressure of all fillter are 0.15MPa

    type DN1 DN2 DN3 ND4 L B H L1 B1 H1 L2 L3 L4
    WGXYZ-16,-25 10 25 50 25 1650 1230 1500 1330 1080 1000 1250 410 420
    WGXYZ-40,-63 25 32 65 32 1800 1430 1550 1480 1280 1050 1400 270 440

    L5 L6 L7 L8 B2 B3 B4 B5 B6 B7 H2 H3 H4 H5 H6 H7
    100 80 120 280 160 200 180 420 280 360 70 78 285 450 890 1132
    140 60 140 300 190 230 200 500 380 400 120 110 285 500 930 1182

    lwo pressure system
    pump type output L/min pressure MPa motor

    type

    power kW velocity rpm
    LBZ-25 25 0.4 Y90S-4,V1 1.1 1400

    high pressure system
    pump type output L/min pressure MPa motor

    type

    power kW velocity rpm
    2.5MCY14-1B 2.5 31.5 Y112M-6,B35 2.2 940

    filling
    temperature

    cooling system

    tanker
    vjolume
    m3
    filter
    area
    m2
    filter
    percision
    mm
    power of
    heater
    kW
    cooling
    area m2
    water
    temperature ℃
    pressure MPa water
    consume m3/h
    40±3 3 ≤30

    0.2≤0.4

    1.5 0.8 0.19 0.05 3*4

    1.pressure controller(2 each of high , low)

    2.pressure gage(1 each of high , low) 

    3.pressure gage switch 

    4.pressure interface of pump 

    5.pressure interface of filling 

    6.differential pressure interface of filter 

    7.duplex pressure gage 

    8.electric contact pressure thermometer 

    9.pressure interface of high pressure


    lwo pressure system
    output L/min pressure MPa motor

    type

    power kW velocity rpm
    63 0.4 Y132S-4,V1 5.5 1400

    high pressure system
    output L/min pressure MPa motor

    type

    power kW velocity rpm
    2.5 31.5 Y112M-6,B35 2.2 940

    filling
    temperature℃

    cooling system

    tanker
    vjolume
    m3
    filter
    area
    m2
    filter
    percision
    mm
    power of
    heater
    kW
    cooling
    area
    m2
    water
    temperature
    pressure MPa water
    consume
    m3/h
    40±3 3 ≤30

    0.2≤0.4

    1.5 0.8 0.19 0.05 3*4
    Inquiry

    Copyright ? Wenzhou Zhonghe Lubrication Equipment Manufacturing Co., Ltd. INC. ALL RIGHTS RESERVED.

    浙ICP備11048852號 Technical Support:lianke

    Sweep with WeChat

    Experience mobile website

    Online Consultation

    Working Day:9:30-21:00
    Weekend:10:00-17:00

    Online Consultation

    Please leave a message
    *

    Title

    *

    Name

    *

    Tel

    *

    E-mail

    *
    国语对白久久香肠,欧美综合区自拍亚洲综合绿色,亚洲精品午夜看片无码专区,中文字幕在线精品男人的天堂 国产精品 亚洲乱伦 久久国产精品99精品国产
    <dfn id="y8k4e"><source id="y8k4e"></source></dfn>
  • <dfn id="y8k4e"><dd id="y8k4e"></dd></dfn>
    <dl id="y8k4e"><s id="y8k4e"></s></dl>
  • <menu id="y8k4e"><code id="y8k4e"></code></menu>